| DM
Series Multifunction Meters |
|
Utility
Substation Feeder Meters |
 |
DMMS
300+
Multifunction
meter with Communication and I/O |
|
|
|
| |
|
|
|
|
|
| |
|
|
| |
|
|
|
Triple
Display Meters |
|
|
DMMS
300+ (Advanced
Multi-Function Meter with Communication and I/O)
|
Features
- Measures
Volts, Amps, Watts, Vars, VA, PF, Frequency,
Watt-Hour, VA/hour, VAR/hour
- Measure
Harmonics to the 31st Order
- Provides
Captured Waveform of Voltage and Current
- Modbus
and DNP 3.0 Protocol
- Set
Point Control With Logical Descriptors
- Relay
Outputs and Pulse Outputs
- Max
and Min for Every Reading
- Fully
Scalable, Field Configurable
- Simply
the Best Power Meter in its Class!!
- Use
in Utility Substations, Industrial Feeder
Metering, OEM and / or any metering application
- AC/DC
Power Supply
|

Multifunction
Power Monitor
with Advanced Capabilities
DMMS
300+ Brochure
DMMS
300+ Instruction Manual
DMMS 300+ Generic Specifications
Modbus Register Mapping
DNP 3.0 assignments for
Futura+ and DMMS 300+ Version 1.14
DMMS
300+ Quick Start Guide
DC
Analog Output Modules
|
The DMMS
300+ advanced multifunction monitoring system
replaces all individual single-function meters and
transducers. This monitor measures volts, amps, frequency
and all power functions, including watts, vars, frequency,
power, watt-hours, var/hours, demand, harmonics and
more. It offers 283 readings in a standard switchboard-size
footprint.
The
DMMS also displays %THD, K factor and harmonic
waveforms. The monitor conducts a comprehensive
power-quality analysis measuring harmonics to
the 31st order for both voltage and current.
Advanced
Communications Capability
- Modbus
PlusNew! See: MP1 data sheet
- Modbus
RTU/ASCII
- DNP
3.0 - For Utility RTUs
- Ten
Channels of Analog Outputs
(0-1 or 4-20mA) See:
DC Analog Output
Modules data sheet
This
unit offers the greatest range of communication
options available in the industry.
|
| 3DAA5 (Triple
Display Ammeter) |
The 3DAA5 simultaneously
displays phases A, B and C. With the press of
a button, it will toggle the neutral. It replaces
traditional utility three-phase amp-demand meters.
The unit monitors maximum and minimum thermal
demand for all phases of current, including the
neutral.
Features
- Harmonic
Measurements to the 31st Order (Including
a Captured Waveform)
- Set
Points and Form C Dry-Contact Relays for
Over and Under Current, and over %THD K Factor
- RS232
or RS485 Digital Communication
- Displays
%THD and K Factor for Each Current Reading
- Great
for Motor Control Centers or Utility Distribution
Feeders
- Four
Channels of 0-1 or 4-20mA Transducer Outputs. See:DC
Analog Output Modules data sheet
|
3 Phase
Amp/Amp
Demand Monitor
3DAA5
Brochure
3DAA5
Instruction Manual
3DAA5
Generic Specifications
3DAA5 Quick Start Guide
|
| 3DVA
120 (Triple
Display Voltmeter) |
The 3DVA120 simultaneously
displays all phase-to-neutral or phase-to-phase
voltages. It provides maximum and minimum readings
based on a user-selectable sliding-window averaging
period.
Features
- RS232
or RS485 Digital Communication
- Harmonic
Measurements to the 31st Order (Including
a Captured Waveform)
- Displays
%THD and K Factor for Each Voltage Reading
- Four
channels of 0-1 or 4-20mA transducer outputs. See:DC
Analog Output Modules data sheet
- Great
for Utility Mains, Generation Plants and
Industrial Mains
|
3 Phase
Volt/Volt
Max-Min Monitor
3DVA120
Brochure
3DVA120
Instruction Manual
3DVA120
Generic Specifications
3DVA120
Quick Start Guide
|
| 3DWA
300 (3D Power Meter) |
This
unit simultaneously displays watts, var, KVA
and power factor. The 3DWA is available in 3-,
2.5- and 2-element connections. It is a full
four-quadrant meter with polarity indicators.
Features
-
Simultaneously Displays Watts,
Vars, KVA and Power Factor
- Highly
Accurate Design
- Field
Scalable
- Two
Channels of Bidirectional 0-1 or 4-20mA Analog
Transducer Outputs. See:DC
Analog Output Modules data sheet
This
unit is commonly used in generator output applications
and utility substations. Technicians especially
like its simplicity. It is also the only WATT/VAR
meter that also displays KVA and power factor.
|
WATT/VAR/PF/VA
Monitor With Max-Min Demand
3DWA300
Brochure
3DWA300
User Manual
3DWA300
Generic Specifications
3DWA300 Quick Start Guide
|
| DWVA
300 (Distribution-Load
Feeder Monitor - Displays Watts, VARs and Amps) |
The
DWVA 300 eliminates single-function meters and
switches to maximize panel space. It offers highly
accurate, true RMS readings. This unit is very
popular for load feeders. It simultaneously displays
watts, VARs and amps. Its easy to read,
rugged and reliable.
Features
The
monitor has a harmonic measurement option capability
to the 31st order. The DWVA 300 also offers
maximum/minimum demand values for all measurements.
The monitor also provides DNP 3.0, Modbus RTU/ASCII
and analog-transducer outputs.
|

WATT/VAR/AMP
Monitor With Max-Min Demand
DWVA300
Brochure
DWVA300
User Manual
DWVA300
User Manual Addendum
DWVA300
Generic Specifications
DWVA300
Quick Start Guide
|
| DWVV
300 (Distribution
Main Monitor - Displays
Watts, VARs and Volts) |
Displaying
precise values for watts, VARs and volts simultaneously,
the DWVV300 power meter, the perfect solution
for monitoring distribution feeder loads.
Features
- Displays
Voltage, Watts and VAR
- Supports
Modbus (RTU & ASCII)
and DNP 3.0 Protocol
- Harmonic
Distortion Analysis
- Max
Demand
- Up
to 6 Analog Outputs (0-1mA
or 4-20mA) See:DC
Analog Output Modules
data sheet
- See:DC
Analog Output Modules
- Heavy-Duty
Construction
With
its rugged construction,
easy-to-read display and
standard ANSI footprint,
the DWVV300 is an ideal
retrofit for replacing
traditional utility distribution-feeder
meters. |

WATT/VAR/VOLTS
Monitor With Max-Min Demand
DWVV300
Brochure
DWVV300
Instruction Manual
DWVV300
Generic Specifications
DWVV300
Quick Start Guide
|
|
|
|
| Electro
Industries/GaugeTech 1800 Shames Dr. Westbury NY 11590 Tel: 1-877-EIMETER